Cooling tower reducer overview and structure sharing

The cooling tower reducer is to realize the new idea proposed by domestic well-known cooling tower experts - the reducer is installed on the top of the central water inlet pipe of the cooling tower, to prevent the cooling tower from being compressed and dynamic load by the fan and the reducer, so as to extend the life of the main cooling tower, improve performance, and reduce the manufacturing cost and noise of the cooling tower. Cooling tower reducer The cooling tower reducer has been put into the market since 2000, and has been verified by industrial tests. It has the characteristics of reliable operation, smooth rotation, high efficiency and low noise. Compared with the domestic cooling tower reducer, its main indicators have reached the leading level. TCJ reducer is mostly used in circular and square countercurrent cooling towers with spray water, and can also be used in cross-flow cooling towers. The reducer is suitable for matching with ultra-low noise cooling towers and is widely used in industrial cooling towers. The cooling tower reducer is composed of a gear box and a motor. The gearbox and motor shaft intersect vertically at a 90 degree Angle. The motor shaft is inserted directly into the input shaft hole of the gearbox, and the motor and gearbox are connected by bolts. This makes the reducer compact and easy to install, assemble, disassemble and maintain. The motor adopts y series three-phase asynchronous motor of domestic design, which conforms to the International Electrotechnical Commission (TEC) standard. The protection level is IP44. According to user requirements, it can also be equipped with IP54 motor, explosion-proof motor or two-speed motor.

2024-07-10


Cooling tower nozzle manufacturers think that cooling tower is a kind

In the industry, the cooling water will contain more impurities, some industrial circulating water temperature is very high, so the industrial cooling tower needs to have strong corrosion resistance, high temperature resistance, hardness and stability.

2024-07-10


Before the cooling tower is officially put into use

2024-09-06 15:26

Before the cooling tower is officially put into use, it should be idled for two hours, and then loaded step by step by 25%, 50%, and 750% of the additional load. Under normal circumstances, should work smoothly, no impact, oil temperature does not exceed 80, temperature rise does not exceed 60. Cooling tower reducer is a cooling tower deceleration equipment, by installing a reducer at the top of the inlet pipe in the center of the cooling tower, prevent the fan and the reducer from rubbing and dynamic load on the tower body, thereby extending the life of the main cooling tower, improving its performance, and reducing the manufacturing cost and noise of the cooling tower.
The cooling tower reducer adopts a pair of medium hyperboloid bevel gears, which is simple and reliable in structure. Gear made of low alloy structural steel, imported high-precision equipment processing, carburizing and grinding. It has the characteristics of strong bearing capacity and low meshing noise. The reducer is composed of a gear box and a motor. The transmission and the motor axis intersect 90 degrees vertically, the motor shaft is directly inserted into the input shaft hole of the transmission, and the motor is bolted to the transmission. This makes the reducer compact and easy to install, assemble, disassemble and maintain.